Abrasive Liquid Transportation
Acid liquor line with high levels of abrasion and sedimentation
Estudo de Caso Nº
21
Cliente
|
Condições de Trabalho
Solução Pexgol
Aplicação
Comprimento
Categorias
The Challenge
Moa Nickel used rubber lined steel pipes to transport acid liquor.
Between 3 and 6 months they required to stop the plant for more than 24 hours, due to sedimentation issues that the steel pipe presented, reducing it inside diameter 60% less.
Furthermore, the steel pipe suffered leaks due to lined releases. Since the first moment that the liquid touched the steel, in a matter of minutes it was causing a leak.
Pexgol Solution
Golan provided Pexgol pipes of 355 mm and 315 mm with mechanical joints, and it only required to stop the plant one year after of the installation.
During that time, and due to the high sedimentation levels, the inside diameter was reduced just 30% less. The repair lasted only 4 hours, and it was done by hammer blows, in order to remove the material that
was obstructing the pipe. At the end, the pipe was functioning without problems.
Pexgol, it not only achieved to raise the production, but also the maintenance expenses were reduced. For every hour that the plant stopped, it cost hundreds of dollars to the company.
Estudos de Caso Relacionados
Alumina Plant: Ore Slurry Transportation
|
Drainage Lines in Underground Mine
|