Hot Water Distribution for Solar Technology
Installation of a New Pexgol Pipeline to Provide Hot Water for a Electro-Thermal Storage System.
Case Study Nº
114
Customer
Raygen
Australia
|
2021
Working Conditions
Pressure: 4 bars | Temperature: up to 90°C / 194°F
Pexgol Pipes
Pexgol 200 (8″), Class 12
Application
Hot water distribution
Lenght
2160 m / 7086 ft
Categories
The Challenge
RayGen is an Australian technology company with world-leading breakthroughs in solar power technology and renewable energy storage.
They required to provide cooling water to their concentrated solar towers. Then the water needed to return from the towers at 90°C to the thermal storage.
Pexgol Solution
The client decided to install a Pexgol system (pipe and fittings) for it’s operation, after considering the following benefits:
- Corrosion resistance at elevated temperature without the need for coatings (compared to metallic piping).
- Ease of installation due to long coil lengths reducing welding/connections and flexibility (compared to metallic and other rigid 6-12 m pipe lengths).
- Low thermal expansion forces allowing direct burying without the need for extra expansion allowance (compared to metallic piping) Pexgol natural bending radius – Using the natural bending capabilities allowed reducing connections, parts and pressure drop.
The pipes were installed under ground without special pipe protection and were insulated using PIR foam sprayed directly around the pipes, after pressure testing. Then backfilled directly on top.
Special Reinforced EF Couplers Series 2 (up to 90ºC) were welded.
Related Case Studies
Vertical Dewatering
Ferrexpo Poltava Mining
Ukraine
|
2019
Transport of Hot Air for Advanced Agriculture
Teva Post
Israel
|
2022
Transport of Silica Arena: HDPE vs Pexgol
Covia Corp
Mexico
|
2019
From Steel to Pexgol: A Plumbing Upgrade for Tel Aviv’s Gordon Pool
Gordon Pool
Israel
|
2023